Bug #3675

Leixen VV-898: Location 1 always downloads as 0.0000 / ERROR

Added by Greg Kopp over 1 year ago. Updated over 1 year ago.

Status:Feedback Start date:05/23/2016
Priority:Normal Due date:
Assignee:- % Done:

0%

Category:-
Target version:0.4.1
Chirp Version:daily Platform:Windows
Model affected:(All models)

Description

When downloading the data from the radio, location 1 always returns 0.0000 as the frequency and ERROR as the name.

I am able to repeat this every time. The memory location, in my example, should be "146.82" with "CARS 2M" as the Name

debug.log - Debug Log (25.8 kB) Greg Kopp, 05/23/2016 04:55 pm

VV-898.img - Radio Image File (8 kB) Greg Kopp, 05/23/2016 04:55 pm

Leixen screen shot.png - Screen Shot (10.6 kB) Greg Kopp, 05/23/2016 04:55 pm

VV-898(fixed).img (8 kB) Jim Unroe, 05/24/2016 03:38 am

Associated revisions

Revision 2761:617ef175811d
Added by Brian Dickman about 1 year ago

[leixen] Filter out-of-bounds audio processor setting, fixes #3675

After doing a clear all reset on the VV-898, the apro setting on
memory 1 is out of range (0xff), but the radio honors it as "off"
anyway. This fix prevents such a memory from throwing an exception on
download.

History

Updated by Jim Unroe over 1 year ago

Greg,
The Audio Processor setting was set to a value that is out-of-range. I changed it to OFF in the attached image. But you can most likely fix it yourself by setting menu 2 (APRO) to some other value and then change it back to OFF.
Jim KC9HI

Updated by Greg Kopp over 1 year ago

Uploading your image seemed to do the trick.

For the record, I even tried doing a factory reset of the radio and that did not solve the problem.

Thanks for the quick response.

73 de KG9O

Updated by Greg Kopp over 1 year ago

Typo. Oops.

73 de KG8O