Making changes tot he squelch threshold settings have no affect on operation of the squelch. You can test this by setting many levels to zero and notice the squelch does not open. This has been noticed by more than one person. either investigate and fix, or please delete this option.


Files

uv5x3(vhf-220-uhf_squelch).py (40.8 KB) uv5x3(vhf-220-uhf_squelch).py Jim Unroe, 11/11/2017 04:31 PM

Related issues

Related to Bug #6809: Radioddity UV-5RX3 Service Settings Not Working / Missing on 220New05/22/2019

Actions
Actions #1

Updated by Jim Unroe over 6 years ago

  • Status changed from New to In Progress
  • Assignee set to Jim Unroe
  • Target version set to 0.5.0
  • Chirp Version changed from 0.4.0 to daily
  • Platform changed from Windows to All

I spent some time working with Baofeng Tech support this evening to investigate this. The problem is actually that the settings currently provided for the VHF squelch settings are actually the 220 squelch settings. The UHF settings should work fine. The VHF settings are missing.

Jim KC9HI

Actions #2

Updated by Jim Unroe over 6 years ago

You can load this module to test the proposed fix for this issue.

Jim KC9HI

Actions #3

Updated by Bernhard Hailer about 4 years ago

  • Status changed from In Progress to Closed
  • Model affected changed from BTECH UV-5X3 to BTech UV-5X3

Appears to be complete.