Project

General

Profile

Actions

Feature #9819

open

TYT TH-350 driver improvement/correction

Added by Bartlomiej Zielinski over 2 years ago. Updated over 2 years ago.

Status:
New
Priority:
Normal
Assignee:
-
Category:
-
Target version:
-
Start date:
04/02/2022
Due date:
% Done:

0%

Estimated time:
Chirp Version:
daily
Model affected:
TYT TH-350
I read the instructions above:

Description

It seems that in TH-350 driver there are more options to be set:

In the settings, the field unknown_1 is mdf_c (values like in mdf_a and mdf_b).

In the settings, the field unknown_2 corresponds to OPNSET menu option (what to display at radio power on). The valid values are: 0 - OFF, 4 - DC (battery voltage), 8 - MSG (message), 12 - PIC (picture).

In the settings, the field unk6 is mem_chan_c (Memory channel in the bottom row).

Additionally, the frequency ranges in my radio are 136-174 MHz, 200-270 MHz, and 400-470 MHz. It is possible to change the lowest frequency from 136 to 128 MHz, and the highest from 470 to 520 MHz.

I attach the downloaded images for different settings of OPNSET option, and also a modified th350.py that I received with [[[https://chirp.danplanet.com/issues/9810]]] issue.


Files

th350(steps added).py (10.2 KB) th350(steps added).py Bartlomiej Zielinski, 04/02/2022 06:48 PM
TYT_TH-350_opnset_dc.img (4.2 KB) TYT_TH-350_opnset_dc.img OPNSET = DC Bartlomiej Zielinski, 04/02/2022 06:48 PM
TYT_TH-350_opnset_msg.img (4.2 KB) TYT_TH-350_opnset_msg.img OPNSET = MSG Bartlomiej Zielinski, 04/02/2022 06:48 PM
TYT_TH-350_opnset_pic.img (4.2 KB) TYT_TH-350_opnset_pic.img OPNSET = PIC Bartlomiej Zielinski, 04/02/2022 06:48 PM
Actions #1

Updated by Bartlomiej Zielinski over 2 years ago

I would also suggest to change the setting description from "Double Standby" to "Triple Standby" or "Triple Watch", because there are 3 frequencies operating at the same time.

Actions

Also available in: Atom PDF