Project

General

Profile

Actions

Bug #6913

closed

TYT TH-UV8000D 6.25kHz step error

Added by Marcel Voorbraak over 4 years ago. Updated over 4 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
-
Target version:
-
Start date:
07/16/2019
Due date:
% Done:

100%

Estimated time:
Chirp Version:
daily
Model affected:
(All models)
Platform:
Windows
Debug Log:
I read the instructions above:

Description

My tyt th-uv8000d is programmed with the origional tyt software. All works fine.
I downloaded the config with chirp and that works fine. But when I want to make some changes I get the error:
Tuning step 6.25 not supported, Frequency requires 6.25kHz step.
So I guess there is a bug in the 6.25 step.


Files

8000d.jpg (221 KB) 8000d.jpg Marcel Voorbraak, 07/16/2019 02:53 PM
Actions #1

Updated by Rick DeWitt over 4 years ago

  • Status changed from New to In Progress
  • Assignee set to Rick DeWitt

Fix is in the release queue. This radio can accept any entered frequency, so a special flag had to be set in the driver.

Actions #2

Updated by Rick DeWitt over 4 years ago

  • Status changed from In Progress to Closed
  • % Done changed from 0 to 100

All better now...