Bug #7031
closedIC-2730A occasional bank index errors
Start date:
09/03/2019
Due date:
09/24/2019
% Done:
100%
Estimated time:
2:00 h
Chirp Version:
daily
Model affected:
ICOM IC-2730A
Platform:
Windows
I read the instructions above:
Description
After downloading from the IC-2730A, when using a stereo extension cable, some of the bank index values have corrupted upper bits set. The lower x1F values are intact so a simple mask will fix the errors. The cause appears to be related to the high-speed clone when using an extension cable.
Updated by Rick DeWitt about 5 years ago
- Status changed from New to Closed
- % Done changed from 10 to 100
Fixed in 20190905 release. If problems with download persist; try turning off High Speed Clone mode in Settings > Other Settings. Then upload your best configuration. It should take about 28 seconds with High Speed Clone disabled. That setting can only be changed in CHIRP, not in the radio.