Project

General

Profile

Actions

Bug #9305

closed

Retevis RT22S Programming Error

Added by Miguel Vega over 3 years ago. Updated over 3 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
-
Target version:
Start date:
08/24/2021
Due date:
% Done:

100%

Estimated time:
Chirp Version:
daily
Model affected:
Retevis RT22S
Platform:
All
Debug Log:
I read the instructions above:

Description

Hi,
I am traying to program the Retevis Radios RT22S but i am getting a message that it says "Error setting Memory: Frequency requires 12.50kHz step"

Can you please help me to understand what do I have to do to program it?

Thank you in advance for your support


Files

Retevis RT22S Programming error.jpg (80.4 KB) Retevis RT22S Programming error.jpg RT22S Error Message Miguel Vega, 08/24/2021 06:25 PM
Frecuencies Required on retevis RT22S.png (195 KB) Frecuencies Required on retevis RT22S.png Frequencies needed on RT22S Miguel Vega, 08/24/2021 06:25 PM
Actions #1

Updated by Jim Unroe over 3 years ago

  • Status changed from New to In Progress
  • Assignee set to Jim Unroe
  • Platform changed from Windows to All

CHIRP needs to be patched. The Retevis programming software does not specify what the valid steps are so CHIRP currently uses its default steps (which does not include the 6.25 KHz or 12.50 KHz steps). I will try to take a look tomorrow to see what it will take to add them.

Jim KC9HI

Actions #2

Updated by Anonymous over 3 years ago

  • Status changed from In Progress to Closed
  • % Done changed from 0 to 100

Applied in changeset commit:7c1cb1a26fff.

Actions #3

Updated by Jim Unroe over 3 years ago

A patch to add the additional 6.25 and 12.5 tuning steps was submitted and accepted. Look for support in the next CHIRP daily build (which should be tomorrow).

Jim KC9HI

Actions

Also available in: Atom PDF