Project

General

Profile

Actions

Bug #9859

closed

MURS-V1: check limit for PTT-LT setting is incorrect.

Added by Jim Unroe almost 2 years ago. Updated almost 2 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Category:
-
Target version:
Start date:
05/07/2022
Due date:
% Done:

100%

Estimated time:
Chirp Version:
daily
Model affected:
MURS-V1
Platform:
All
Debug Log:
I read the instructions above:

Description

The setting range for PTT-LT is 0-50. The MURS-V1 driver currently forces values above 30 down to the factory default value of 5. The upper check limit should be 50.

Jim KC9HI

Actions #1

Updated by Jim Unroe almost 2 years ago

  • Status changed from In Progress to Resolved
  • % Done changed from 0 to 100

Patch submitted.

Jim KC9HI

Actions

Also available in: Atom PDF