Project

General

Profile

Actions

Feature #1037

closed

Missing columns for Baofeng UV-B5/UV-B6

Added by Predrag Supurovic over 10 years ago. Updated almost 10 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
-
Target version:
Start date:
07/30/2013
Due date:
% Done:

100%

Estimated time:
Chirp Version:
daily
Model affected:
Baofeng UV-B5/UV-B6
I read the instructions above:

Description

Memories table does not show all columns available for Baofeng UV-B5/UV-B6.

Missing columns are:

Cross mode
BCL
Reverse Duplex
PTT ID
Compander

All those field are available in single memory edit dialog.

Actions #1

Updated by Jim Unroe over 10 years ago

  • Assignee set to Jim Unroe
  • Target version set to 0.4.0

I noticed the Cross Mode column missing the other day. I haven't had a chance to look at it yet. I'll probably need help from Dan and/or others to resolve it but I do plan to fix it.

The other 'extra' settings will only be in the right-click Edit menu.

Jim KC9HI

Actions #2

Updated by Predrag Supurovic over 10 years ago

Jim Unroe wrote:

The other 'extra' settings will only be in the right-click Edit menu.

Why? It is much user friendly to have them in table view. After all there is an option for user to select which fields are shown in table. Why those fields are treated differently?

Actions #3

Updated by Dan Smith over 10 years ago

It's a design detail. While not ideal, the memory editor spreadsheet attempts to handle the most common fields supported by a wide set of radios. In order to keep it simple, we just stuff radio-specific things into the edit box. This could be refactored in the future, but it's not high on the list.

Note that you can select multiple memories and right-click-edit them all together, applying only selected changes to all of them at once.

Actions #4

Updated by Predrag Supurovic over 10 years ago

Dan Smith wrote:

Note that you can select multiple memories and right-click-edit them all together,
applying only selected changes to all of them at once.

I use that, but problem is I cannot easily see how thing are set. i have to open edit for each memory.

Actions #5

Updated by Jim Unroe almost 10 years ago

  • Status changed from New to Closed
  • % Done changed from 0 to 100

The requested settings are now supported in the memory spreadsheet editor or the right-click edit menu as indicated.

Actions

Also available in: Atom PDF