Bank Grid: Inappropriate Action w/Click in Freq or Memory Loc columns

Added by Craig Jones 11 months ago. Updated 11 months ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
-
Target version:
Start date:
06/07/2023
Due date:
% Done:

100%

Estimated time:
Chirp Version:
next
Model affected:
PowerWerx and possibly others
Platform:
Windows
Debug Log:
I read the instructions above:

Description

(This is a preliminary report, so I don't forget to add it later. I will either refine this report or delete it.)

While developing and testing the PowerWerx driver, the banks tab works fine except that if you click in either the Freq column or the Memory Location column, it acts as if you clicked in the column for bank 9 or bank 10, respectively (those being the last two columns on the right.)

Actions #1

Updated by Dan Smith 11 months ago

  • Assignee set to Dan Smith
  • Target version set to chirp-py3

I came here to say "that's ridiculous" but.. Yeah I see to too. Bizzare. I repro'd with the FT-7800 driver and it looks like it's wrapping around to the last and second to last columns, whichever those are.

Actions #2

Updated by Dan Smith 11 months ago

  • Status changed from New to Closed
  • % Done changed from 0 to 100
Actions