Project

General

Profile

Actions

Bug #11684

open

corrupted slots & can't skip some slots

Added by Galen Thurber about 1 month ago. Updated about 1 month ago.

Status:
New
Priority:
Normal
Assignee:
-
Category:
-
Target version:
-
Start date:
11/15/2024
Due date:
% Done:

0%

Estimated time:
Chirp Version:
next
Model affected:
Icom IC-V80
Platform:
Windows
Debug Log:
I read the instructions above:
Yes

Description

(Describe what you were doing)
using chirp 20241114 windows10 python3.10?
trying to find corrupted slots of wonky V80E[serial ...31]
created a "filled" set of slots, each slot was set to 154.6 named ABCDE
then uploaded
then downloaded to find what slots are corrupted and other problems
unit serial ..31 has known bad slots and wrong firmware label for slots 100-109 [they show as 110-119]

(Describe what you expected to happen)
be able to skip selected slots

(Describe what actually happened instead)
when trying to change to SKIP, skip fails to change

(Has this ever worked before? New radio? Does it work with OEM software?)
worked before? unsure
New old stock, Icom says they are genuine [I sent them an unit from 12 I bought],
my opinion is the units might have failed QC, Icom said only the batteries were weak unit ok.
Skipping works on VS80 1.1 software


Files

config.txt (1.28 KB) config.txt Galen Thurber, 11/15/2024 12:21 PM
Icom_IC-V80_31-filled-post.img (3.81 KB) Icom_IC-V80_31-filled-post.img Galen Thurber, 11/15/2024 12:21 PM
win_system_info.txt (55.8 KB) win_system_info.txt Galen Thurber, 11/15/2024 12:21 PM
debug_log.txt (223 KB) debug_log.txt Galen Thurber, 11/15/2024 12:21 PM
Actions #2

Updated by Dan Smith about 1 month ago

I'm really not sure what you're asking or reporting. Can you give some more detail please?

Actions

Also available in: Atom PDF