Hi all I've been going mad trying all solutions throughout this site and cannot for the life of me get CHIRP to read from my QYT KT-7900D.
I have read through the btech.py and noticed after reading the version name from the packaged disc that the is for the radio I have is
Model: QYT790
MCU-Version: VC4284

Would this be why chirp is not reading and I am getting errors for radio ID?

Can this ID be changed or is there a firmware to correct this?

Thanks


Files

IMG_0656.JPG (2.19 MB) IMG_0656.JPG Leigh Harris, 10/09/2017 10:25 AM
Actions #1

Updated by Jim Unroe about 7 years ago

  • Status changed from New to Feedback

A patch was just submitted to add the VC4284 MCU version.

Jim

Actions #2

Updated by Bernhard Hailer over 4 years ago

  • Target version set to chirp-legacy

Does the patch work for you?

Actions #3

Updated by Jim Unroe over 4 years ago

  • Status changed from Feedback to Resolved
  • Assignee set to Jim Unroe
  • % Done changed from 0 to 100

Support for additional MCU version added.