Bug #8297

kenwood TS-480HX/SAT Writing to memory causes memory channels to be stored in SPLIT mode

Added by Paul Dluehosh 10 months ago. Updated 5 months ago.

Status:Closed Start date:10/02/2020
Priority:Normal Due date:03/08/2021
Assignee:Rick DeWitt % Done:

100%

Category:-
Target version:chirp-daily Estimated time:3.00 hours
Chirp Version:daily Platform:Windows
Model affected:Kenwood TS-480SAT/HX

Description

While writing data to regular memories in a TS-480HX, the first channel is stored in split mode albeit both frequencies stored are the same so there is no problem with operation (simulates simplex mode!) but the SPLIT indicator is displayed on the control head. Using the same file to program a TS-480SAT, ALL memory channels were stored in split mode! The exception is that one of the channels where I did program a split, it was put in memory correctly. Using the "M>VFO" button function, the info in the memory channel is entered into the A and B memories, which it should do, but it overwrites data already in the A and B memory instead of just overwriting one of the memories if the memory channel were not stored in SPLIT mode. Please contact me if you have any questions.

Thanks, 73,
Paul -- N4PD

Associated revisions

Revision 3478:183d10b81b36
Added by Rick DeWitt 5 months ago

[ts480] Bug fixes for issues #8297 and #8877 Kenwood TS-480
#8297 fix for split mode support, #8877 fix for 67Htz PL download

History

Updated by Rick DeWitt 6 months ago

  • Assignee set to Rick DeWitt

I will look into this. Gotta get the loaner radio back.

Updated by Rick DeWitt 5 months ago

  • Due date set to 03/08/2021
  • Target version set to chirp-daily
  • % Done changed from 0 to 100
  • Estimated time set to 3.00
  • Model affected changed from (All models) to TS-480SAT/HX

Bug fix patch is tested, ready to submit.
TS-480 does not use +/- offsets, only split mode.

Updated by Rick DeWitt 5 months ago

  • Status changed from New to Resolved

Patch submitted for next build.

Updated by Bernhard Hailer 5 months ago

  • Status changed from Resolved to Closed
  • Model affected changed from TS-480SAT/HX to Kenwood TS-480SAT/HX

Patch applied.

Also available in: Atom PDF