Project

General

Profile

Actions

Bug #9987

closed

lost settings info

Added by Gary Neville over 1 year ago. Updated over 1 year ago.

Status:
Closed
Priority:
Normal
Assignee:
-
Category:
-
Target version:
Start date:
08/15/2022
Due date:
% Done:

0%

Estimated time:
Chirp Version:
daily
Model affected:
UV-25X2
Platform:
Windows
Debug Log:
I read the instructions above:

Description

I originally set up my UV-25x2 with no issues. The settings tab in the Chirp download was there I even set up items I wanted to be the way I wanted them. I recently updated all my frequencies. I copied the frequencies from my UV5R and pasted them in my download from the uv25x2, I uploaded to radio and it finished, I went back to review my settings and noticed the settings tab was blank. I can still manually set all the settings but would like to do it thru Chirp. Let me know if you need anything else from me, Thank you


Files

BTECH_UV-25X2_20220815.img (16.2 KB) BTECH_UV-25X2_20220815.img Gary Neville, 08/15/2022 07:26 PM
BTECH_UV-25X2_20220815(fixed).img (16.2 KB) BTECH_UV-25X2_20220815(fixed).img Jim Unroe, 08/15/2022 09:32 PM
Actions #1

Updated by Jim Unroe over 1 year ago

Your BTech UV-25X4 has an out-of-range/invalid menu 47 (OFFSET) of the display line A VFO. The other three VFOs have unusual values as well (but at least they are in-range).

You can probably fix it yourself by...

tap the [EXIT/ABCD] button as needed to select display line A.

tap the [V/M] button as needed to select VFO (frequency) mode.

edit menu 47 [OFFSET] to have a valid value (000.000-999.999). Try 000.600 or 005.000.

download from your radio into CHRIP

The Settings tabs should now be visible.

Or just use the attached CHIRP Radio Images (*.img) file. It is a copy of your "image" with A VFO's OFFSET set to [000.000].

Jim KC9HI

Actions #2

Updated by Gary Neville over 1 year ago

That fixed it thank you very much! Sorry it took so long to get back to you but trying to find where to answer you all. Thanks again!

Actions #3

Updated by Jim Unroe over 1 year ago

  • Status changed from Feedback to Resolved

Gary Neville wrote:

That fixed it thank you very much! Sorry it took so long to get back to you but trying to find where to answer you all. Thanks again!

You are welcome.

Jim

Actions #4

Updated by Dan Smith over 1 year ago

  • Status changed from Resolved to Closed
Actions