Project

General

Profile

Actions

Bug #10911

open

Quansheng UV-K6 Scanlist Issue

Added by Ken Hansen about 1 year ago. Updated about 1 year ago.

Status:
New
Priority:
Normal
Category:
-
Target version:
-
Start date:
10/25/2023
Due date:
% Done:

0%

Estimated time:
Chirp Version:
next
Model affected:
Quansheng UV-K6
Platform:
Windows
Debug Log:
I read the instructions above:

Description

Manually programmed 3 channels into my UV-K6, read radio into CHIRP_Next, then added over 3 dozen channels from Repeaterbook, saved to UV-6R, all worked as expected. When I long press "*(scan)" button to activate scanning of programmed channels, I can only scan the three channels I manually programmed - the imported channels programmed thru CHIRP_Next were not included in the scan.

After investigating the issue I selected "Show Extra Fields" I noticed that the manually programmed channels had the value "1+2" in the Scanlists column, the imported channels had that field empty.

I request that the "Scanlists" field default to "1+2", so that the radio acts as a user would reasonably expect. Manually programmed channels have this setting, so I feel this can be made the default.

The "Skip" column displayed in the default view for this radio serves no purpose - it can not be set to anything, and it does not seem to be part of the way memory channel scanning works, perhaps it should be removed from the default display, perhaps replaced by the "scanlists" field?


Files

Quansheng UV-K5 UV-K6 Scan Note.odt (5.23 KB) Quansheng UV-K5 UV-K6 Scan Note.odt Overview of radio scan function Ken Hansen, 10/26/2023 09:19 AM
Actions

Also available in: Atom PDF