Project

General

Profile

Actions

Bug #9461

closed

KENWOOD TK732G

Added by MICHEL ANTOINE DRIVET AMADOR over 2 years ago. Updated about 1 year ago.

Status:
Closed
Priority:
Normal
Assignee:
-
Category:
-
Target version:
Start date:
10/20/2021
Due date:
% Done:

0%

Estimated time:
Chirp Version:
daily
Model affected:
Kenwood TK-372G
Platform:
Windows
Debug Log:
I read the instructions above:

Description

CHIRP DOESN´T READ THE RADIO IDENTIFIES IT CORRECTLY BUT AT THE END OF THE READING PROCEDURE SENDS AN ID ERROR


Files

debug.log (26.2 KB) debug.log MICHEL ANTOINE DRIVET AMADOR, 10/21/2021 05:23 PM
debug.log (41.3 KB) debug.log MICHEL ANTOINE DRIVET AMADOR, 10/22/2021 08:30 PM
debug.log (31.3 KB) debug.log MICHEL ANTOINE DRIVET AMADOR, 11/07/2021 05:11 PM
Actions #1

Updated by MICHEL ANTOINE DRIVET AMADOR over 2 years ago

Wrong Kenwood radio, ID or unknown variant, see LOG output. THIS ERROR SHOWS ON SCREEN

Actions #3

Updated by MICHEL ANTOINE DRIVET AMADOR over 2 years ago

WITH THE NEW VERSION SAME ERROR

Actions #4

Updated by Bernhard Hailer almost 2 years ago

  • Priority changed from High to Normal
  • Model affected changed from TK372G to Kenwood TK-372G
Actions #5

Updated by Pavel Milanes almost 2 years ago

Hi OM, thanks for the debug log. (driver's author here)

The operation fails as the last byte of the ident string are not the same, look it for yourself:

DEBUG: Full ident string is:
DEBUG: 000: 50 33 37 32 30 06 fb *f1*   P3720...

DEBUG: Starting the download from radio
DEBUG: Wrong Kenwood radio, ID or unknown variant
DEBUG: 000: 50 33 37 32 30 06 fb *00*   P3720...

That means that the radio has the TRUNKING addon board installed. Reviewing the drivers identification schema:

"P3720\x06": (32, 450, 470, "K")
"P3720\x07": (32, 470, 490, "K1")
"P3720\x08": (32, 490, 512, "K2")
"P3720\x09": (32, 403, 430, "K3")

You can see it's like a "K" variant and must work from 450 to 470 Mhz, it's supported.

Also, the driver does not support radios with the TRUNKING addon installed (last f1 byte means that) as it changes the memory handling a bit.

If you can access the OEM software please read it, deactivate the TRUNKING option and upload the programing again.

I must work with chirp then.

Cheers, Pavel CO7WT.

Actions #6

Updated by Pavel Milanes almost 2 years ago

  • Status changed from New to Feedback
Actions #7

Updated by Bernhard Hailer almost 2 years ago

Please let us know whether this response helped, so that we can close the ticket.

Actions #8

Updated by Bernhard Hailer about 1 year ago

  • Status changed from Feedback to Closed

No more feedback by submitter

Actions